Toronto Commercial HVAC services cooling towers for office towers, hospitals, campuses and industrial plants across Toronto and the GTA. We handle mechanical repair, fill and drift eliminator replacement, fan and gearbox rebuilds, spring start-ups and fall cleanouts, water treatment and legionella sampling for open and closed loop towers from BAC, Marley SPX, Evapco and Delta.
Cooling towers fail on two fronts. Mechanically, fill scales and collapses, drift eliminators break, gearboxes wear and fans go out of balance, so the tower rejects less heat and the chiller burns more energy. On the water side, poor treatment lets scale, corrosion and biological growth build up, including legionella. Ontario expects tower operators to control and document that risk, so records matter as much as the cleaning itself.
Spring and fall cleanouts typically cost $2,800 to $8,500. Fill replacement runs $12,000 to $35,000, and fan and gearbox rebuilds $18,000 to $45,000.
What Does Cooling Tower Service Include?
Start-up and shutdown
Spring start-up and fall cleanout: drain, clean and disinfect the basin and distribution system, inspect fill and drift eliminators, check fan, gearbox and motor, and restart or winterize.
Mechanical repair and rebuild
Gearbox rebuilds, fan and driveshaft replacement, motor work, float valves, nozzles and basin heaters.
Fill and drift eliminators
Removal of scaled or collapsed fill, new fill media and new drift eliminators to restore heat rejection and cut drift.
Water treatment and legionella
Automated chemical and biocide feed, conductivity control, routine sampling and a records binder per tower to support Ontario Reg 611 compliance.
Cooling Tower Cost Guide
| Work | Typical range |
|---|---|
| Spring start-up or fall cleanout | $2,800-$8,500 |
| Fill and drift eliminator replacement | $12K-$35K |
| Fan and gearbox rebuild or replacement | $18K-$45K |
| Water treatment program | Per tower per season |
Signs Your Cooling Tower Needs Attention
- Condenser water temperature running high on hot afternoons.
- Visible scale, algae or slime in the basin or on the fill.
- Gearbox noise, oil leaks or fan vibration.
- Water loss from drift or overflow.
- Gaps in sampling or treatment records.
Towers, Chillers and Controls Together
A tower that cannot reject heat makes the chiller work harder, so we maintain both together under our commercial chiller service programs. Tower fans on VFDs and condenser water reset strategies are handled by our BMS and HVAC controls team.
Cooling Tower Service Across Toronto and the GTA
We service towers on downtown and North York office towers, hospitals and universities, Scarborough and Etobicoke campuses and industrial plants along Hwy 410 in Brampton and Dixie Road in Mississauga. Our Brampton legionella retrofit replaced fill and drift eliminators and added automated biocide feed inside a one-week shutdown.